C004387_07_CR3500_User_Manual - 12
Save Settings
1.8.4 - RS232 (Serial) Cable Installaon Guide
1. Aach the RS232 (Serial) Cable to the CR3500.
2. Connect the RS232 (Serial) cable to a serial port on the computer (Figure 1.18). There is no need to power o the computer.
3. The RS232 (Serial) interface has an oponal 5V/1.5A power supply (Figure 1.19). If you have a power supply, plug the power supply
adapter into the RS232 (Serial) cable and then plug the power adapter into a wall socket (Figure 1.20).
4. Once properly connected, the CR3500 will power on and beep.
5. For RS232 (Serial) mode scan M418_02 (below). If the power supply is not connected scan M074_02 (below).
6. Scan the Save Sengs Code (M188_02).
RS232 (Serial) RS232 (Serial) Mode
Factory Reset No Power Supply Save Sengs
Warning: Code Corporaon approved power adapter must be used. Reader failure due to use of
incorrect power adapter will void warranes.
Figure 1.19
Figure 1.18
Figure 1.20
RS232 (Serial)
Factory Default Sengs
Mode: RS232 (Serial)
One Way Mode
Baud Rate: 57600
Stop Bits: 2
Data Bits: 8
Parity: None